MANAGER
Colliers International
HOURS
Monday to Friday 8:00 a.m. to 6:00 p.m (excluding statutory holidays).
ENVIRONMENTAL STATUS
LEED®-EB Gold Certified
ARCHITECT
G. Edward Lutman
BASE BUILDING STRUCTURE
John Stephenson Consultants Limited
BASE BUILDING ELECTRICAL/ MECHANICAL
MMM Group
NUMBER OF FLOORS
15 (above grade)
CROSSOVER FLOORS
5, 10, 15 (typical)
CEILING HEIGHT
8’9” (typical)
COMMON AREA FINISHES
Common areas on multi-tenant floors feature granite flooring with carpet surround, men’s and women’s washrooms both equipped with hands free, push button access are finished with contemporary granite and ceramic tile. Each main floor lobby is equipped with hands free, push button accessibility.
EXTERIOR FINISHES
The building exterior walls consist of exposed aggregate precast concrete panels and a glazing curtain wall.
WINDOWS
The vision glass and spandrels are constructed with reflective glass surface.
ELEVATORS
At 1 Robert Speck: 5 passenger elevators and 1 combined passenger/service elevator.
At 2, 3 and 4 Robert Speck: 4 passenger elevators and 1 combined passenger/service elevator.
HVAC (Zones/Floor)
Heating is provided by multiple boilers and cooling is supplied by chillers and a cooling tower system. A typical perimeter floor has approx. 30 HVAC zones. The HVAC systems are controlled by a building automation system with remote access capability.
LIGHTING
T8 27 watt fluorescent tubes with electronic ballasts, 50 foot candles
DATA CAPABILITY
Multiple fibre optics service providers: Allstream, Bell, Blink, Rogers, Terago, and Telus
LIFE SAFETY SYSTEMS
Aboveground floors are equipped with a wet sprinkler/standpipe system and underground levels with a dry system. Each building contains two separate exit stairs accessible from each floor. At each exit on every floor, there is a manual pull station, emergency telephone and a fire hose cabinet with a fire extinguisher. Exit luminaries are installed throughout each building. Each building has a dedicated emergency diesel generator that powers lighting and other essential equipment in the event of an outage. The fire detection system has a voice communication capability. All 4 chiller rooms are equipped with refrigerant leak detection systems interlocked with exhaust fans. There is a CO detection system in the underground parking garage at 1 Robert Speck Parkway. Ventilation is provided by exhaust fans at the other 3 buildings.
SECURITY SYSTEM
24 hour security desk and guard patrol with numerous closed circuit cameras monitoring entry points and public areas
AFTER HOURS SYSTEM
The complex is equipped with a diebold card access system that is controlled and managed in-house. A 24/7 Security Command Centre is situated at 1 Robert Speck Parkway with camera surveillance screens running 24/7.
1 ROBERT SPECK PARKWAY | 2 ROBERT SPECK PARKWAY | 3 ROBERT SPECK PARKWAY | 4 ROBERT SPECK PARKWAY | |
PARKING |
|
|
|
|
YEAR OF COMPLETION | 1990 | 1978 | 1987 | 1983 |
AREA |
|
|
|
|
TYPICAL FLOOR AREA |
|
|
|
|
EFFICIENCY RATIOS |
|
|
|
|
CEILING GRID |
|
|
|
|
ELECTRICAL DESIGN |
|
|
|
|
FLOOR LOADING
(Live / Dead Load) |
75 lb / 110 lb | 50 lb / 70 lb | 75 lb / 110 lb | 50 lb / 70 lb |